SS-22
https://www.choudharypumps.com/wp-content/uploads/2021/05/Khyatee-Single-Phase-Pump-Control-Panels-2.pdf / Piece
  • Specifications
  • Features
  • Application

1. System Settings

Working Voltage 120 – 300 VAC, 50 Hz
 Low  Voltage Start  130 VAC ± 5 VAC
 Auto Off Voltage  At  120 VAC ± 5 VAC

 

2. Protections / Setting Parameters

Protection Design  Current Sensing
Pump Current Range  1 – 20 Amps / as required
Sr. No. Parameter Setting Range Default setting Trip Time Delay LED
1 Overload Fixed > 140 % 15 sec YES
2 Dryrun Fixed < 75 % 15 sec YES

 

3. Reset

 Resetting mode Reset switch

 

4. Output Relay Contact 

 Relay Mechanical life  10 lac operations
Dielectric Strength 2.2 KV , 50 Hz for 1 min

 

5. Enclosure & Mounting

 Enclosure Material Compact, rust proof Engineering Plastic panel box
 Mounting Wall Mounting with 4 screw M4 × 15 mm
Temperature  5 to 60°C
 Humidity  Up to 90% RH

 

6. Dimensions & Weight

 L × W × D (mm) 109 × 119  × 75 mm
Power Consumption  Less than 5 Watts
 Weights gms.

1. Technology :

  • Micro controller based software technology

 

2. Current Range / HP :

  • 1 – 20 Amps. or as required / 0.5 to 2 HP

 

4. Protection :

  • Electronic Overload Fixed
  • Remote Sensing Dryrun Fixed

 

5. Special Feature :

  • Heavy Duty DC Coil Contactor
  • Agriculture
  • Irrigation
  • Domestic