1. System Settings
Working Voltage | 120 – 300 VAC, 50 Hz |
Low Voltage Start | 130 VAC ± 5 VAC |
Auto Off Voltage | 120 VAC ± 5 VAC |
2. Protections / Setting Parameters
Protection Design | Current Sensing |
Pump Current Range | 1 – 20 Amps / as required |
Sr. No. | Parameter | Setting Range | Default setting | Trip Time Delay | LED |
---|---|---|---|---|---|
1 | Overload | Fixed | > 140 % | 15 sec | YES |
2 | Dryrun | Fixed | < 75 % | 15 sec | YES |
3. Special Features
Sr. No. | Parameter | Working Sensors | Display | LED |
---|---|---|---|---|
1 | Universal Two Tank Fully Automatic Water Level Controller | Float Switch / Magnetic Switch / Metal Sensor | UTF / LTE | YES |
4. Reset
Resetting mode | OFF switch |
5. Output Relay Contact
Relay Mechanical life | 10 lac operations |
Dielectric Strength | 2.2 KV , 50 Hz for 1 min |
6. Enclosure & Mounting
Enclosure Material | Compact, rust proof Engineering Plastic panel box |
Mounting | Wall Mounting with 4 screw M4 × 15 mm |
Temperature | 5 to 60°C |
Humidity | Up to 90% RH |
7. Dimensions & Weight
L × W × D (mm) | 128 × 80 × 48 mm |
Power Consumption | Less than 5 Watts |
Weights | gms. |
1. Technology :
2. Current Range / HP :
3 . Protections :
4 . Special Features :
5. Starter :
© 2021 Choudhary Pumps and Pipe. All Rights Reserved.