KTC 22
https://www.choudharypumps.com/wp-content/uploads/2021/05/Khyatee-HyderoPneumatic-Automation-Panels-1.pdf / Piece
  • Specifications
  • Features
  • Application

1. System Settings

 Input Voltage (AC)  140 – 290 VAC, 50 Hz
 On voltage (cold start)  Minimum 140 VAC ± 5 VAC
 Auto Off voltage  At 125 VAC ± 5 VAC

 

2. Protections / Setting Parameters

 Protection Design  Current Sensing
 Pump Current Range  1 – 20 Amps or as required
Sr. No. Parameter Setting Range Default setting Trip Time Delay Display LED
1 Overload 20% – 60% > 140 % 15 sec YES YES
2 Dryrun 60% – 95% < 75 % 15 sec YES YES
3 High Voltage 250 – 300 280 V ± 2 V Fixed HIU YES
4 Low Voltage 110 – 180 V 140 V ± 2 V Fixed LOU YES
5 Extremely High Current Fixed Fixed 3 sec EHC YES

 

3. Timers

Sr. No. Parameter Setting Range Default setting Display LED
1 Power ON Timer 3 sec – 300 sec 60 sec ± 3 sec PONT YES
2 Dryrun Autostart Timer 5 – 720 min OFF OFF YES

 

4. Reset

 Resetting mode  Manual by OFF switch

 

5. Output Relay Contact

 Relay Mechanical life  10 lac operations
 Dielectric Strength  2.2 KV , 50 Hz for 1 min

 

6. Enclosure & Mounting

 Enclosure Material  Rust Proof, Shock Proof, Industrial  ABS Enclosure
 Mounting  Wall Mounting with 4 screw M4 × 15 mm
 Temperature  5 to 60°C
 Humidity  Upto 90% RH

 

7. Dimensions & Weight

 L × W × D (mm)  220 × 135 × 75  mm
 Power Consumption  Less than 5 Watts
 Weights  gms.

1. Technology :

  • Micro controller based software technology

 

2. Current Range / HP :

  • 1 – 20 Amps. / 0.5 to 2 HP or as required

 

3. Display :

  • Digital Voltmeter (100 to 300 V)
  • Digital Ammeter (1 – 30 Amps. / as required)

 

4. Protections :

  • Electronic Overload (Site Settable)
  • Remote Sensing Dryrun (Site Settable)
  • High / Low Voltage(Site Settable)
  • Extreme High Current(Short Circuit)

 

5. Special Feature :

  • Two tank Fully Automatic Universal Water Level Controller Auto Start On Power Failure
  • Pressure Switch Connection Facility Available
  • Float Bypass Facility Available

 

6. Timers : 

  • Power On Timer
  • Dryrun Auto Start Timer ( Off – 5 – 720 mins.)

 

7. Capacitors : 

  • Running Capacitor – One (max. 60 Mfd )
  • Agriculture
  • Irrigation
  • Domestic

Related Products

KTC 22 PNPN
KTC 22 PNPN
KTP 99 WLC
KTP 99 WLC
KDP 99 WLC
KDP 99 WLC
SS-22 WLC
SS-22 WLC

Share your requirement with us