KDP 99 WLC
https://www.choudharypumps.com/wp-content/uploads/2021/05/Khyatee-HyderoPneumatic-Automation-Panels-1.pdf / Piece
  • Specifications
  • Features
  • Application

1. System Settings

 Input Voltage (AC)  140 – 290 VAC, 50 Hz
 On voltage (cold start)  Minimum 140 VAC ± 5VAC
 Auto Off voltage  At 125 VAC ± 5VAC

 

2. Protections / Setting Parameters

 Protection Design  Current Sensing
 Pump Current Range  2 – 20 / 2 – 26 / 2 – 45 Amps.
Sr. No. Parameter Setting Range Default setting Trip Time Delay Display LED
1 Overload 20% – 60% > 140 % 15 sec YES YES
2 Dryrun 60% – 95% < 75 % 15 sec YES YES
3 High Voltage 250 – 300 280 V ± 2V Fixed HIU YES
4 Low Voltage 110 – 180 V 280 V ± 2V Fixed LOU YES
5 Extremely High Voltage Fixed Fixed 3 sec EHC YES

 

3. Timers

Sr. No. Parameter Setting Range Default setting Display LED
1 Power ON Timer 3 sec – 300 sec 60 sec ± 3 sec PONT YES
2 Motor OFF Timer 5 – 720 min OFF OFF YES
3 Dryrun Auto Start Timer NA 5 to 720 mins. DRAT YES

 

4.Special Features

Sr. No. Parameter Working Sensors Display LED
1 Two Tank Fully Automatic Universal Water Level Controller Float Switch / Magnetic Switch / Metal Sensor UTF / LTE YES

 

5. Monitoring

 Digital Voltmeter  100 – 300V
 Digital Ammeter  2 – 20 / 2 – 26 / 2 – 45 Amps. / as per Hp.

 

6. Reset

 Resetting mode  Manual by OFF switch

 

7. Output Relay Contact

 Relay Mechanical life  10 lac operations
 Dielectric Strength  2.2 KV , 50 Hz for 1 min

 

8. Enclosure & Mounting

 Enclosure Material  Rust Proof, Shock Proof, Industrial  ABS Box
 Mounting  Wall Mounting with 4 screw M4 × 15 mm
 Temperature  5 to 60°C
Humidity  Upto 90% RH

 

9. Dimensions & Weight

 L × W × D (mm)  295 × 260 × 97 mm
 Power Consumption  Less than 5 Watts
 Weights  2989 gms.

1. Technology :

  • Micro controller based software technology

 

2. Current Range / HP :

  • 2 – 20 / 2 – 26 / 2 – 45 Amps for 2 / 3 / 5 HP.

 

3. Display :

  • Digital Voltmeter (100 to 300 V)
  • Digital Ammeter (2 – 20 / 2 – 26 / 2 – 45 Amps. / as per current range)

 

4. Protections :

  • Starting Capacitor Cut Off Timer
  • Electronic Overload ( Site Settable )
  • Remote sensing Dryrun ( Site Settable )
  • High / Low Voltage ( Site Settable )
  • Extreme High Current( Short Circuit )

 

5. Special Feature :

  • Two Tank Fully Automatic Universal Water Level Controller with Auto start On Power Failure
  • Indications for Upper Tank Full & Lower Tank Empty

 

6. Timers : 

  • Motor Off Timer  (SS)  – 5 to 720 mins.
  • Power On Timer For Auto start
  • Dryrun Auto Start Timer (SS) Off – 5 to 720 mins.

 

7. Starter :

  • Heavy Duty DC Coil Contactor

 

8. Capacitors :

  • Starting Capacitor and Running Capacitors as per HP.