KDP 22
https://www.choudharypumps.com/wp-content/uploads/2021/05/Khyatee-Single-Phase-Pump-Control-Panels-2.pdf / Piece
  • Specifications
  • Features
  • Application

1. System Settings

Input Voltage (AC)  140 – 290 VAC, 50 Hz
 On voltage (cold start) Minimum 140 VAC ± 5VAC
Auto Off voltage At 125 VAC ± 5VAC

 

2. Protections / Setting Parameters

 Protection Design Current Sensing
 Pump Current Range 1 – 20 Amps. / 1 – 26 Amps. or as required
Sr. No. Parameter Setting Range Default setting Trip Time Delay Display LED
1 Overload 20% – 60% > 140 % 15 sec YES YES
2 Dryrun 60% – 95% < 75 % 15 sec YES YES
3 High Voltage 250 – 300 280 V ± 2V Fixed HIU YES
4 Low Voltage 110 – 180 V 140 V ± 2V Fixed LOU YES
5 Extremely High Current Fixed Fixed 3 sec EHC YES

 

3. Timers

Sr. No. Parameter Setting Range Default setting Display LED
1 Starting Capacitor Cut OFF Timer NA Fixed CCT YES
2 Power ON Timer 3 sec – 300 sec 60 sec ± 3 sec PONT YES
2 Motor OFF Timer 5 – 720 min OFF OFF YES

 

4. Monitoring

Digital Voltmeter  100 – 300 V
Digital Ammeter  1 – 30 Amps.

 

5. Reset

 Resetting mode  Manual by OFF switch

 

6. Output Relay Contact

Relay Mechanical life  10 lac operations
Dielectric Strength 2.2 KV , 50 Hz for 1 min

 

7. Enclosure & Mounting

 Enclosure Material  Rust Proof, Shock Proof, Industrial  ABS Enclosure
Mounting Wall Mounting with 4 screw M4 × 15 mm
Temperature 5 to 60°C
Humidity  Upto 90% RH

 

8. Dimensions & Weight

 L × W × D (mm)  265 × 200 × 80 mm
Power Consumption Less than 5 Watts
Weights  gms.

1. Technology :

  • Micro controller based software technology

 

2. Current Range / HP :

  • 1 – 20 Amps. / 0.5 to 2 HP or as required.
  • 1 – 26 Amps, / 3 HP or as required.

 

3. Display :

  • Digital Voltmeter (100 to 300 V)
  • Digital Ammeter (1 – 20 Amps / 1- 26 Amps. / as required)

 

4. Protections :

  • Starting Capacitor Cut Off Timer
  • Electronic Overload (Site Settable)
  • Remote sensing Dryrun (Site Settable)
  • High / Low Voltage (Site Settable)
  • Extreme High Current (Short Circuit)

 

5. Special Feature :

  • Bore Flushing Facility – Easy to activate, removes Mud, Water & Dust from the Bore during Installation.

 

6. Timers : 

  • Motor Off Timer  (SS)  OFF – 5 – 720 mins.
  • Power On Timer

 

7. Starter :

  • Heavy Duty DC Coil Contactor

 

8. Capacitors :

  • Starting Capacitor and Running Capacitors as per HP.
  • Agriculture
  • Irrigation
  • Domestic

Related Products

KLM 22
KLM 22
KSD 22
KSD 22
KSR 22
KSR 22

Share your requirement with us