1. System Settings
Input Voltage (AC) | 250 – 470 VAC, 50 Hz |
On voltage (Cold Start) | 250 VAC |
Auto Off voltage | 200 VAC |
2. Protections / Setting Parameters
Pump Current Range | 2 – 60 Amps. |
Sr. No. | Parameter | Setting Range | Default setting | Trip Time Delay | LED |
---|---|---|---|---|---|
1 | Phase Failure | Fixed | Fixed | 4 sec ± 1 sec | YES |
2 | Reverse Phase | Fixed | Fixed | 4 sec ± 1 sec | YES |
3 | Voltage Unbalance | Fixed | Fixed | 4 sec ± 1 sec | YES |
4 | Overload | 20% – 60% | > 140 % | 15 sec | NO |
5 | Dryrun | 60% – 95% | < 75 % | 15 sec | YES |
3. Timers
Sr. No. | Parameter | Setting Range | Default setting | LED |
---|---|---|---|---|
1 | Power ON Timer | 3 sec – 300 sec | 60 sec ± 3 sec | NO |
2 | Star Delta Timer | 3 sec – 300 sec | 10 sec ± 2 sec | NO |
3 | Dryrun Auto Start Timer | 5 – 720 min | OFF | NO |
4. Reset
Resetting mode | Manual by OFF switch |
5. Output Relay Contact
Relay Mechanical life | 10 lac operations |
Dielectric Strength | 2.2 KV , 50 Hz for 1 min |
6. Enclosure & Mounting
Enclosure Material | Rust proof, Shock Proof, ABS Enclosure |
Mounting | Wall Mounting with 4 screw M4 × 15 mm |
Temperature | 5 to 60°C |
Humidity | Up to 90% RH |
7. Dimensions & Weight
L × W × D (mm) | 130 x 77 x 77 mm |
Power Consumption | Less than 5 Watts |
Weights | gms. |